    • 摘要: 乌达矿区地表及浅部存在大面积煤田火区、小窑火区,且火区范围较大、隐蔽性强、复燃率高,火区难以得到彻底治理。为实现火源位置及范围的精准探测,从红外热成像技术、电磁法和测氡法探测机理入手,基于红外热成像技术、电磁法和测氡法探测火区基础理论,提出了“红外−电磁−测氡”联合精准探测技术。使用T335型红外成像仪、电磁仪和FD213α能谱氡测量仪对12号井筒附近区域进行现场实测并收集数据,利用“红外−电磁−测氡”联合精准探测技术对收集的数据进行处理与分析,初步确定小窑隐蔽火源的边界与面积。采用测温法和测气法观测验证钻孔中的温度及CO浓度,结合前期探测结果和12号煤层巷道布置情况对火区位置进行核实。最后采用钻孔注浆技术治理火区,通过收集束管监测系统各组分气体的数据和复测氡结果验证火区治理效果。结果表明,测温法和测气法探测结果与“红外−电磁−测氡”技术圈定小窑火源范围基本一致。此次试验圈定火区面积1 351.38 m2,施工注浆钻孔4个,注浆量31 140 m3;注浆后钻孔温度由210 ℃下降到30 ℃,监测钻孔内CO降至0.005 5%以下,C2H6及C2H4浓度降低至0,C2H2浓度降低至0.004%以下,氡值恢复正常水平,火区治理工作效果显著。

       

      Abstract: Large coalfield fire zones and abandoned small-mine fire zones are widely distributed in the surface and shallow strata of the Wuda Mining Area. These fire zones are extensive, highly concealed, and prone to reignition, making complete fire control difficult. To achieve precise identification of the location and extent of concealed fire sources, an integrated infrared, electromagnetic, and radon detection method was developed based on the detection principles of infrared thermal imaging, electromagnetic surveying, and radon measurement. A T335 infrared thermal imager, electromagnetic surveying equipment, and an FD213α energy-spectrum radon detector were used for field measurements in the area near Shaft No. 12. The acquired data were jointly analyzed to preliminarily delineate the boundary and area of the concealed fire source. Borehole temperature and CO concentration were then measured to verify the detection results, and the fire-zone location was further confirmed in combination with the layout of roadways in the No. 12 coal seam. Borehole grouting was subsequently applied to control the fire zone, and the treatment effectiveness was evaluated using gas data from a tube-bundle monitoring system and repeated radon measurements. The results show that the fire-source area delineated by borehole temperature and gas measurements was generally consistent with that identified by the integrated infrared, electromagnetic, and radon detection method. The delineated fire zone covered an area of 1 351.38 m2. Four grouting boreholes were constructed, with a total grout volume of 31 140 m3. After grouting, borehole temperature decreased from 210 ℃ to 30 ℃, CO concentration fell below 0.005 5%, C2H6 and C2H4 concentrations decreased to zero, C2H2 concentration dropped below 0.004%, and radon levels returned to the normal range. These results demonstrate that the proposed integrated detection method can effectively identify concealed fire sources in abandoned small coal mines and provide reliable support for subsequent fire-zone treatment.

       

    /

    返回文章
    返回